Pipe Wall Thickness: Schedule, Class and What Actually Matters
Three labelling systems describe the same physical dimension: schedule (Sch 40, Sch 80), class (Class 150, 300), and plain wall thickness in millimetres. Confusing them is one of the most common causes of a wrong order.
Schedule is a wall thickness, not a pressure rating
Schedule numbers started as a ratio of wall thickness to diameter, which is why Sch 40 on a 2 inch pipe is 3.91 mm but on a 24 inch pipe is 17.48 mm. The number is an index, not a pressure class.
| NPS | Sch 40 wall | Sch 80 wall |
|---|---|---|
| 2" | 3.91 mm | 5.54 mm |
| 4" | 6.02 mm | 8.56 mm |
| 8" | 8.18 mm | 12.70 mm |
| 12" | 10.31 mm | 17.48 mm |
Class belongs to the fitting, not the pipe
Class 150, 300, 600 describe flange ratings. A Class 150 flange has a pressure-temperature curve; the pipe connected to it is still defined by schedule or wall thickness. Mixing the two in an enquiry is how buyers receive Schedule 40 pipe for a Class 300 line.
What actually determines the wall you need
- Design pressure - the hoop stress calculation, with corrosion allowance
- Design temperature - allowable stress falls with temperature
- Corrosion allowance - often 1.5 to 3 mm in process service
- External loads - supports, wind, and in some cases soil
- Standard - ASME B31.3, B31.1 and EN 13480 give different allowables
A 6 inch line at 10 bar and 20 °C needs far less wall than the same line at 300 °C, even at the same pressure, because the allowable stress drops.
Practical checks before ordering
- Convert everything to plain wall thickness in millimetres, then confirm against the standard's table
- State the standard in the order, not just the schedule
- Ask for wall thickness measurement at both ends of each length - eccentric wall is a real defect
- For welded pipe, confirm whether the wall is measured on the plate before forming (typical) or after
How we supply pipe
We quote by wall thickness and standard, with the schedule shown as a cross-check:
- Seamless and ERW, 1/2" to 24", Sch 10 to XXH
- Wall thickness verified at both ends and reported on the inspection sheet
- EN 10204 3.1 certificate per heat, with the standard and grade stated
- Beveled ends, caps and coating as part of the packing
Send the line class, medium, design pressure and temperature. We will come back with the wall thickness the standard requires, and flag it if the schedule in your enquiry does not match.
Related: A106 Gr.B seamless pipe, A53 ERW pipe, A106 vs A53 vs A333
Frequently asked questions
Is Schedule 40 the same as Class 150?
No. Schedule is a wall thickness index; Class 150 is a flange pressure rating. They are separate systems.
How do I convert schedule to millimetres?
Use the standard's table. Sch 40 is 3.91 mm at 2 inch but 17.48 mm at 24 inch.
Does higher temperature need thicker wall?
Yes, because allowable stress falls with temperature even at the same pressure.